综合久色I久久btI国产日韩在线免费观看I小柔的淫辱日记(hI亚洲 高清 成人 动漫I美国三级视频I巨乳在线播放I在线视频综合网I亚洲乱码在线观看I超碰caoporI欧美激情电影一区二区I人妻av无码一区二区三区I91精品国产91久久久久久吃药I韩国一区二区三区在线观看I日本r级电影在线观看I亚洲视频成人I欧美另类z0z变态I国产精品免费一区二区三区在线观看I久久久999成人I毛片专区I风韵丰满熟妇啪啪区老熟熟女I天海翼中文字幕I五月天看片I久久99热这里只频精品6学生I国产成人精品一区二区在线I日本熟妇成熟毛茸茸

Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
SM 302 safety relay

     

     As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

(1) Redundancy

(2) Difference

(3) Self-detection

        How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


▊ SM-302 programmable safety controller
1666939573713918.png

· Is a configurable safety controller, which supports the input of various safety product components.

·Maximum support for 3 sets of dual-loop inputs.

·Iso 13849-1 performance index PLe

·Built-in self-diagnosis function for fault detection

·Modbus protocol communication

·Input and output fault indicator light

·Safety certification: PL e, Cat: 4


Product selection

product name

model

Safety input

Safe output

brand

Programmable safety controller

SM-302

3CH

2NO

LHS
explain

Up to 3 sets of dual-channel security products can be entered.

The programming software defines the field safety products by itself.

Official website programming software download connection.:http://lhsafety.com.cn/showinfo-257-118-0.html


safety performance

·Performance level (PL): PLE

·Safety category (cat.): cat.4.

·Task time (TM): 20 years.

·Diagnostic coverage (DC/DC AVG): 99%

·Safety integrity level (SIL): SIL3

·Hardware fault margin (HFT): 1

·Safety Failure Score (SFF): 99%

·PFHD: 1.78e-9/h

·Stop category: 0/1               

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standard EN 60204-1.


Main technical parameters

Power supply characteristics

·Power supply voltage: 24VDC

·Voltage range: 20~30VDC

·Current loss: ≤100mA(24VDC)

Input characteristics

·Input current: ≤10mA(24VDC)

·Conductor resistance: ≤15Ω

·Input equipment: emergency stop button, safety door, two-hand button,

·Safety light curtain, magnetic switch, etc

·Input channel: 3

output characteristic

·Number of contacts: 2NO (safety output)

·Contact material: AgSnO2

·Contact fuse protection: 10A is fast, 6A is slow.

·Switching capacity: 5A/230VAC;; 5A/24VDC

Time characteristic

·Suction buffer time:≤100ms

·Release buffer time:≤30ms

·Recovery time:

         Emergency stop operation:≤30ms

         Power failure:≤1000ms

·Recovery time:

         Emergency stop operation:≤30ms

         Power failure:≤100ms

·Short-term interruption of power supply:20ms

Communication characteristics

·Baud rate: 38.4kbps (fixed)

·Communication length: ≤1000m

·Networking capacity: ≤10 units


Environmental characteristic parameters

·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

·Vibration frequency: 10Hz~55Hz

·Vibration amplitude: 0.35mm

·Operating temperature: -20℃~+60℃

·Storage temperature: -40℃~+85℃

·Relative humidity: 10%~90%

·Overvoltage grade: Ⅲ

·Pollution level: 2

·Altitude: ≤2000m

·Rated isolation voltage: 250VAC.

·Rated impulse voltage: 6000V(1.2/50us)

·Insulation strength: 1500VAC for 1min.

·Electrical clearance and creepage distance: in accordance with EN60947-1.

302 22.10.27處理過原圖加了影印.png


Functional application parameters

functional block diagram

Typical application

圖片3.png

圖片4.png


Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

Control Logic: CH1&CH2

Reset mode: manual reset.

Output delay: 0s

Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


Wiring diagram

Power Supply 

1.png

correspondence

1655948458157829.png

input

1655948540921377.png1655948633175148.png1655948716671157.png
6.png7.png
9.png10.png

reset

11.png12.png

feedback

13.png14.png

output

15.png

     


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 欧美网站视频 | 伊人网黄色 | av片在线免费 | 美女露出粉嫩尿囗让男人桶 | 日本高清wwww | 清纯唯美亚洲色图 | 亚洲熟妇一区二区 | 色天堂在线视频 | 亚洲免费人成 | 香蕉视频在线网站 | 黑人黄色一级片 | 亚欧日韩av | www一区 | 国产精品无码99re | 国产91在线视频 | 亚洲日本在线播放 | 国产网站黄| 奇米狠狠干 | 一级黄色性生活视频 | 果冻av在线 | 色噜噜狠狠一区二区三区果冻 | 日韩欧美视频免费在线观看 | 欧美四级在线观看 | 2020国产精品视频 | 欧美欧美欧美 | 国产一区第一页 | 久久亚洲精选 | 久色福利 | 第五色婷婷 | 日韩黄频 | 又黄又粗又硬 | 日韩伊人网 | 中文字幕免费视频观看 | 美女的诞生免费观看在线高清 | 日韩男女性生活视频 | 天天夜碰日日摸日日澡性色av | 亚洲天堂美女视频 | 视频h在线 | 中文字幕欧美色图 | 免费观看一级特黄特色大片 | 欧美不卡二区 |