D3SL-T/RFID electromagnetic locking type
1.png

·Electromagnetic force locking 500N

·Adopt a small plane "electromagnetic" locking structure.

·Support 16 to 20 cascaded connections.

·Design of permanent magnet in matcher

·Small body, simple installation

·Full-angle eye-catching indicator light

·No abrasive powder will be produced.

·IP65/IP67 protection


D3SL-T/RFID Series Selection Table

Locking mode

deploy

model

Output mode

coded system

Electromagnetic locking

normalized form

D3SL-T-DB-N2

NPN

universal coding

D3SL-T-DB-N1

NPN

Unique coding

D3SL-T-DB-P2

PNP

universal coding

D3SL-T-DB-P1

PNP

Unique coding

Advanced type

D3SL-T-DG-N2

NPN

universal coding

D3SL-T-DG-N1

NPN

Unique coding

D3SL-T-DG-P2

PNP

universal coding

D3SL-T-DG-P1

PNP

Unique coding


Technical parameters of D3SL-T/RFID

type

Hinged door

small-sized

M12 connector

normalized form

High functional type

working distance

Sao(off-0n)

4mm

Sar(on-0ff)

4mm

Response time

Lock → release

155ms

Release → lock

155ms

Detection → Non-detection

20ms+2ms* (Number of cascaded connections -1)

Non-detection → detection

300ms+25ms* (Number of cascaded units -1)

Control output

(OSSD output)

Output mode

Transistor output "2

Maximum load current

150mA

Residual voltage (on)

Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

OFF voltage

Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

leakage current

Up to 0.5mA

Maximum load capacity

0.8uF

Load connection resistance

Max. 2.5 Euro

AUX output

(Non-safety system output)

Output mode

Transistor output

Maximum load current

50mA

Residual voltage (ON)

Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

external input

(Short-circuit current)

Safety input

About 1.5 max 2

Locking control input OSSD action switching input

About 2.5 mA

Reset /EDM input

About 5mA (high functional type only)

EDM select input

About 2.5 mA (high functional type only)

Power Supply 

Power supply voltage

24 VDC 10% including ripple (P-P)10% Class2

consumed power

<5W

protective circuit

Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

Environmental resistance

Enclosure protection grade

IP65/67(IEC60529)

Operating ambient temperature

20 degrees below zero to 55 degrees without freezing.

Storage ambient temperature

25 degrees below zero to 70 degrees without freezing.

Using ambient humidity

5% to 95%RH

Storage environment humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

Applicable standards

ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


Model description of safety switch

 1728548977520914.png 



hookup

Standard type (NPN, cascade)

Standard (PNP, cascade)

1719978292858022.png

Standard type (NPN, cascade)

1719978426648983.png

Standard (PNP, cascade)

1719978725470017.png

Functional (NPN, cascade)

Functional (PNP, cascade)

1719979076106539.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

"1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

3. Only use EDM: Turn off the EDM selection (pink line).

K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

High functional type (NPN, cascade)

1719979521976024.png

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch

Functional (PNP, cascade)

1719979875434469.png

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

1. Use EDM and reset: wiring as shown in the figure.

2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

3. Only use EDM: Turn off the EDM selection (pink line).

K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

S: reset switch

Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

*1. Make ?EDM and reset: wire as shown in the figure.

2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

3. EDM only: Turn off the EDM selection (chalk line).

K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

S: reset switch


Indication of indicator light

1719983442751425.png


Product ruler diagram

1719983681983392.png


Selection Method of Safety Switch D3SL-T/RFID Series

1728618489514684.png



Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 少妇自拍视频 | 亚洲精品国产熟女久久久 | 欧美精品aaa | 中文字幕十一区 | 欧美精品videos另类日本 | 丰满少妇大力进入av亚洲 | 一区二区视频在线播放 | 久久黄色录像 | 欧美激情91| 97成人精品 | 欧美熟妇交换久久久久久 | 欧美在线视频免费观看 | free性娇小hd第一次 | 名人明星三级videos | 青青草久久伊人 | 99re伊人| 久久久久久美女精品啪啪 | 修仙淫交(高h)h文 | 欧洲grand老妇人bbw | 久久久久久久999 | 久久人人爽人人爽 | 欧美中文字幕 | 一级a毛片免费观看久久精品 | 国产做爰免费视频观看 | 精品国产乱码久久久久久影片 | 亚洲午夜精品一区三区五区97 | 天天操天天射天天爱 | 国产88av | 免费成人一级片 | 黄色片在线免费观看视频 | 日韩精品你懂的 | 天天操天天插天天干 | 中国性老太hd大全69 | 日韩草逼视频 | 在线调教| 男人的天堂色偷偷 | 亚洲另类一区二区 | 日韩aaa| 奇米狠狠| a免费在线| 很黄的网站在线观看 |